Project installation
Deluge, MVWS and HVWS system
Factoryclix (Proactive Industrial Private Limited), Ahmedabad, supplies and installs Deluge, MVWS and HVWS system across Gujarat. Deluge valves and medium- or high-velocity water spray, supply through commissioning. The scope covers Deluge valve and trim, Open nozzles or water-spray nozzles, Pipe. The standards named on this page are NBC 2016. Desks in Vadodara, Padal (Kheda) and Bharuch. Other states are taken on enquiry. Call +91 99131 17860 or send an RFQ.
Price on request / Get a quote
Scope
This page is the supply, installation, testing and commissioning of a deluge system, a medium-velocity water spray system, or a high-velocity water spray system. Deluge opens a set of open nozzles over a zone when detection trips the valve. MVWS and HVWS are the water-spray nozzle systems used on transformers, cable galleries, vessels and similar surfaces. The hydrant and sprinkler page remains the wet and dry sprinkler and hydrant scope. A foam-water system is the foam page. The hardware is the deluge valve, the detection or the release, the open nozzles or the water-spray nozzles, the pipe, and the test. Nozzles are taken from listings on Factoryclix, including the water-spray nozzles already filed under Fire Protection. A make on a listing is listed on Factoryclix. The make is the name stored on that listing.
Standards
The engineering desk already cites IS 15325 and NFPA 15 for water spray. Those are the codes this installation follows. NBC 2016 is the occupancy reference already used on the fire pages. A nozzle listing that stores UL or FM is described with that mark only on the product page, because the listing stores it. This service page does not add a mark that the product page does not have. Design density and the nozzle k-factor are taken from the code and from the nozzle listing. They are not printed here as a single number for every hazard. An open deluge nozzle and a water-spray nozzle are not treated as the same device. The schedule names which one is used in each zone. A strainer, a pressure switch and the valve trim are included when the selected valve needs them, and they are omitted from the offer when the enquiry is only a nozzle replacement.
Steps
The desk takes the equipment to be protected, the plan, the water supply, and whether the release is electric, pneumatic or hydraulic. The zone is drawn. Nozzles are placed for the surface or the volume the code requires. The deluge valve and the trim are selected to the flow. Pipe is sized from that flow and from the residual pressure at the valve. Installation includes supports, the valve trim, and the drains. The test is a trip test of the valve and a discharge observation of the pattern, or the test the code allows when a full discharge is not possible. The record states which test was done. A pump or a tank that cannot support the flow is reported. It is not hidden. The work is arranged from Proactive Industrial Private Limited, C-119, Siddhivinayak Business Tower, Makarba, Sarkhej, Ahmedabad, Gujarat 380051, with branch desks at Vadodara, Padal (Kheda) and Bharuch. Call +91 99131 17860 or email help@factoryclix.com. Price is on request. This page does not publish a rate, a client name, or a finished-project list.
What the client provides
Send the equipment drawings, the transformer or vessel sizes if that is the hazard, the water-supply residual, and the detection you want to use. If the pump house is not part of this order, send the available flow and pressure. A preferred nozzle make can be named when it is listed. Photographs of the equipment and the pipe route help. Do not send a density copied from another plant. The density for this job is set from the hazard in front of us. Isolation of a transformer or a vessel, if the work is next to live equipment, is the plant’s permit. The installation crew does not decide that isolation.
Deliverables
The file contains the zone drawing, the nozzle schedule, the valve and trim list, the pipe sizes, and the test record. As-built marks are included when installation is in the order. A hydraulic calculation is included when the pipe network needs it. The file is not a rate list. A fire NOC drawing set is the Fire NOC service if the authority submission is also ordered.
- Zone drawing
- Nozzle schedule
- Test record
What drives the cost
The quotation moves with the protected surface or the number of zones, the nozzle count, the deluge-valve size, the pipe length and diameter, the detection method, access around transformers or vessels, and whether a full discharge test is permitted. A tall structure or a live substation that must be worked under a permit changes the programme. No rate per nozzle, no rate per zone and no rate per metre of pipe is published here. Water-supply works outside the valve are quoted only when they are in the enquiry. A live-substation permit that limits the working hours is written into the programme on the quotation.
Typical turnaround
Programme after the equipment drawings and the water supply.
Related products and guides
Products for this system
- HD Fire Protect 1 Inch High Velocity Water Spray Nozzle UL Listed
- HD Fire Protect 1/2 Inch Medium Velocity Water Spray Nozzle UL FM
- HD Fire Protect Custom Engineered Deluge Skid Fire Protection System
- HD Fire Protect Deluge Skid Model DSK Pre-Assembled UL Listed Valve
- HD Fire Deluge Valve 100 NB
- PCD Deluge Valve Control Panel (Standard / Flameproof)
- HD Fire Deluge Valve H3 80 NB with Horizontal Trim & Gong Bell
- HD Fire Protect Deluge Valve Model A Fire Protection Cast Iron
Questions
Who is a Deluge, MVWS and HVWS system contractor in Gujarat?
Factoryclix (Proactive Industrial Private Limited) does Deluge, MVWS and HVWS system from Ahmedabad, with desks in Vadodara, Padal (Kheda) and Bharuch. Visits cover Gujarat. Call +91 99131 17860 or send an RFQ, and the desk writes the quotation after the enquiry.
What does Deluge, MVWS and HVWS system include?
This page is the supply, installation, testing and commissioning of a deluge system, a medium-velocity water spray system, or a high-velocity water spray system. Deluge opens a set of open nozzles over a zone when detection trips the valve. Price is on request until the quotation is written.
Which standards apply to Deluge, MVWS and HVWS system in India?
The standards already named for Deluge, MVWS and HVWS system are NBC 2016. A code appears here only because this service uses it. The note cites the clause once the site data is in.
How long does Deluge, MVWS and HVWS system take?
Typical turnaround is programme after the equipment drawings and the water supply. That is the time already stated on this page.
What documents do I need to give for Deluge, MVWS and HVWS system?
Send the equipment drawings, the transformer or vessel sizes if that is the hazard, the water-supply residual, and the detection you want to use. If the pump house is not part of this order, send the available flow and pressure. A preferred nozzle make can be named when it is listed.
What decides the cost of Deluge, MVWS and HVWS system?
The quotation moves with the protected surface or the number of zones, the nozzle count, the deluge-valve size, the pipe length and diameter, the detection method, access around transformers or vessels, and whether a full discharge test is permitted. A tall structure or a live substation that must be worked under a permit changes the programme. No rate per nozzle, no rate per zone and no rate per metre of pipe is published here.
Do you work outside Gujarat?
Enquiries from other states are taken on the same desk when the scope matches; site visits are agreed per job. The desks stay in Ahmedabad, Vadodara, Padal (Kheda) and Bharuch.
Last reviewed 27 November 2026. Prepared by the Factoryclix engineering desk.
Related pages
- Fire hydrant and sprinkler systems
- Gas suppression systems
- Nitrogen injection for transformers
- Fire alarm and fire and gas detection
- About Factoryclix and Proactive Industrial Private Limited
- Contact the Ahmedabad desk
- Send an RFQ
- Factoryclix locations in Gujarat
- Ahmedabad registered office
- Vadodara branch at Raopura
- Bharuch branch
- Site visits to Dahej from Bharuch
- Site visits to Vapi
- Site visits to Sanand from Ahmedabad
- Industrial work across Gujarat
Recent work
Approved project references are not published on this page. This block stays hidden until that list is supplied. No client is named here.
Service areas
Ahmedabad is the registered office. Vadodara and Bharuch are branches. Dahej, Vapi and Sanand are served from those desks. There is no branch page invented for a city that does not have one.
