Factoryclix
FM-200, IG-541 and CO2 fire suppression, designed to the right IS standard
Factoryclix (Proactive Industrial Private Limited), Ahmedabad, FM-200, IG-541 and CO2 fire suppression is handled across Gujarat. The standards named on this page include IS 15517, IS 15501, IS 15506 and IS 15525. Some rooms cannot take water. Desks in Vadodara, Padal (Kheda) and Bharuch. Other states are taken on enquiry. Call +91 99131 17860 or send an RFQ.
When the room cannot take water
Some rooms cannot take water. Factoryclix designs, supplies, installs and tests gaseous fire-extinguishing systems for industrial and commercial rooms in Gujarat: FM-200 (HFC-227ea), IG-541 and carbon dioxide. Design is coordinated from the Ahmedabad office. Site work is also taken through the Vadodara, Padal (Kheda) and Bharuch branches. You name the room and the agent. We do not treat a sample room as a package, and we do not pick the agent for you on this page.
Get the IS number right
IS 15493:2021 sets the general requirements. IS 15517 is the part for HFC-227ea, which is FM-200. IS 15501 is the part for IG-541. IS 15506 is IG-55. IS 15525 is IG-100. IS 15528 is carbon dioxide, both total flooding and local application. Use the number that matches the agent. A quotation that cites the wrong part is not a small paperwork error.
Storage volume is not the same from one agent to the next. FM-200 is stored as a liquid and the cylinder volume is smaller than for an inert gas such as IG-541, which is stored as a high-pressure gas. Occupied rooms and unmanned rooms are not interchangeable. Carbon dioxide at its design concentration is not for a space that people normally occupy. People must not remain in a room that is being flooded with CO2. FM-200 is commonly considered where people work, and only when the design concentration stays inside the exposure limits written in the standard. They still leave the room on the pre-discharge alarm. The longer comparison is in FM-200, IG-541 and CO2. Design notes we already publish are in the fire suppression knowledge hub.
Calculators and the desk
Use the free clean-agent quantity calculator for FM-200 and for the inert-gas methods the desk already runs there. The room that appears when the page opens, 10 m by 8 m by 3.5 m, is only a starting value. You must change the length, the width and the height to the enclosure you have. Leaving the starting room in place does not describe your server room or your panel room. That calculator does not compute an IS 15528 carbon dioxide quantity. The tool page says so, and this page repeats it so the two are not confused. CO2 quantity is handled on the suppression Project Desk, to IS 15528.
Figures from either place are an enquiry estimate. A licensed engineer stamps anything submitted to an authority. The equipment maker’s listed software still governs the final cylinder and pipe design. A room integrity test is a required step, not an optional extra. Without the test you cannot show that the room will hold the agent for the time the standard requires. Door fans, dampers and the sealing of cable entries are part of that proof. They are not a line you drop to save a visit.
Installation in Gujarat
Supply, installation and testing are the gas suppression systems service. The service area is Gujarat, worked from Ahmedabad, Vadodara, Padal and Bharuch. Price is confirmed on the quotation after the room, the agent and the specification are known. This page does not print a rupee figure, a cylinder count for a typical room, or a lead time. When you enquire, state the room use, whether people are normally inside, the agent you prefer if you have already chosen one, and whether the panel and the wiring sit in another contract. Those points keep the enquiry off the sample room the calculator opens with.
Questions
Which IS standard covers CO2 systems?
IS 15528. FM-200 is IS 15517. IG-541 is IS 15501. IS 15493 gives general requirements.
Does the free calculator cover CO2?
No. The clean-agent calculator is for the clean-agent and inert-gas methods used on the desk. CO2 is calculated on the suppression Project Desk to IS 15528.
Is FM-200 suitable for an occupied server room?
It is commonly used in occupied rooms when the design concentration stays within the exposure limits in the standard. People should still leave on the pre-discharge alarm.
Do you need a room integrity test?
Yes. Without it you cannot show the room will hold the agent for the required time.
Are the online figures a final design?
No. They are an enquiry estimate. A licensed engineer and the equipment maker’s listed software stamp the issue.
Will you quote a rupee figure on this page?
No. Price is confirmed on the quotation after the room, the agent and the specification are known.
Who is a FM-200, IG-541 and CO2 fire suppression contractor in Gujarat?
Factoryclix (Proactive Industrial Private Limited) does FM-200, IG-541 and CO2 fire suppression from Ahmedabad, with desks in Vadodara, Padal (Kheda) and Bharuch. Visits cover Gujarat. Call +91 99131 17860 or send an RFQ, and the desk writes the quotation after the enquiry.
Do you work outside Gujarat?
Enquiries from other states are taken on the same desk when the scope matches; site visits are agreed per job. The desks stay in Ahmedabad, Vadodara, Padal (Kheda) and Bharuch.
Last reviewed 27 November 2026. Prepared by the Factoryclix engineering desk.
Related pages
- Gas suppression systems
- FM-200 vs IG-541 vs CO2: Choosing a Gas Suppression System in India
- Fire protection products
- HVAC products
- About Factoryclix and Proactive Industrial Private Limited
- Contact the Ahmedabad desk
- Factoryclix locations in Gujarat
- Ahmedabad registered office
- Vadodara branch at Raopura
- Bharuch branch